A-1 Roofing & Insulation Systems
Call now
Call now
Website
Call
With 35 years of experience we are excited to bring to you what we have learned and seen proven to work. From our many years of experience we know what type of roofing systems work in every type of situation. We get excited at the opportunity to help our customers figure out what tailored roof system we think would work for them. Whether your roof is a EPDM, MOD-BIT, TPO, PVC, HYPALON, or a TAR and Gravel roof.

We will work with you from start to finish to assess the roofs needs and find out what it needs for a good quality fix. If possible we want to save you from a potential costly re-roof. We will tailor a Foam or coating roofing plan that is best for your roof and your wallet. A-1 Roofing and Insulation Systems has been in business since 1985. With millions of Square feet of roofs out there, we have seen what systems stand the test of time and which ones have not.

Our main concern is that you have your problems fixed right the first time! A-1 is passionate about our quality of work.
Services
You know who likes spending money on a roof?
Nobody - And the reason is simple.
You can't see it.
In fact, typically you forget it exists, until it isn't functioning properly and it leaks.
For this reason, the roof gets neglected and is allowed to deteriorate beyond repair.
Building owners that allow this to happen, end up spending a lot more money on their roofs.
Conversely, building owners that are proactive and spend money on maintenance, turn their roofs into their greatest asset.
How is this possible?
Roofs can be restored with 1.5 of sprayed on Polyurethane Roofing Grade Foam.
The foam is then covered with elastomeric coatings.
These coatings are usually sprayed on in two separate passes.
These coatings are extremely tough and U.V. stable and reflect 90% of the suns harmful rays off of your your roof.
When your Foam and Coating roof gets old and is showing signs of deterioration, the roof can be cleaned and power washed, and resurfaced with a new layer of coating.
This will make your old foam roof a new foam roof again.
Restoration is the future of Commercial roofing.
The old logic of installing a hot black roof roof is disappearing.
A-1 Roofing and Insulation has caught the vision for potential Re-Covering.
Your old EPDM, TPO, MOD-BIT, HYPOLON, PVC roofs no longer need to be torn off when they reach the end of their expected life.
If the building owner is proactive and does not let his roof get over 25% saturated.
There is a high probability that your roof can be saved by re-surfacing it.
Silicone coating products have been revolutionizing the standard practices of roofing.
The R-value is a modern fairy tale.
It's a fairy tale that has been so touted to the American consumer that it now has a chiseled in-stone status.
But the saddest part of this fairy tale is that the R-value by itself is almost a worthless number.
Consider the R-value of an insulation after it has been submerged in water or as a 20 mile-per-hour wind blows through it.
In either of these scenarios, the R-value of fiber insulations goes to zero.
But those same conditions barely affect solid insulations.
Below grade waterproofing is an application that must be done quickly and correctly, or it will have lasting implications on the structure.
Several methods exist to waterproof a building from roll on products to applied sheeting, but most of these applications take time to apply and may require a long set time or cure time.
In order to decrease the time spent on below grade waterproofing, polyurea and polyurea hybrid chemistry is being used to provide a quick cure time and return to service.
Without a quick return to service, job sites can be shut down days for the correct waterproofing to cure and be backfilled.
Reviews
Review A-1 Roofing & Insulation Systems

Be the first to review A-1 Roofing & Insulation Systems.

Write a Review